Menu

Star on GitHub · 3.2k

CVE-2014-0750

7.5 · HIGH

Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMP…

Published Jan 25, 2014geCWE-22EPSS 69.83%

Overview

CVE-2014-0750 is a high-severity vulnerability affecting ge intelligent_platforms_proficy_hmi\%2fscada_cimplicity. It was published on January 25, 2014 and has a CVSS 2.0 base score of 7.5 (HIGH).

This vulnerability has a CVSS 2.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical description

Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622.

Remediation

Check the references section for vendor advisories and patches from ge. Update intelligent_platforms_proficy_hmi\%2fscada_cimplicity to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected products

VendorProductVersionsStatus
geintelligent_platforms_proficy_hmi\%2fscada_cimplicity0Affected

Frequently asked questions

What is CVE-2014-0750?

CVE-2014-0750 is a high-severity vulnerability affecting ge intelligent_platforms_proficy_hmi\%2fscada_cimplicity. It was published on January 25, 2014 and has a CVSS 2.0 base score of 7.5 (HIGH).

How severe is CVE-2014-0750?

This vulnerability has a CVSS 2.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2014-0750?

Check the references section for vendor advisories and patches from ge. Update intelligent_platforms_proficy_hmi\%2fscada_cimplicity to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2014-0750?

CyberStrike is an open-source, AI-augmented pentesting engine. Rather than flag a version number, it tests whether an issue like CVE-2014-0750 is actually reachable in your own applications and APIs, then verifies each finding before reporting it. That tells you if the weakness is a real, exploitable risk in your environment or a false positive you can safely deprioritize.

Related HIGH CVEs from 2014

View all