CVE-2015-1012

7.5 · HIGH
Published Mar 25, 2019 pfizer CWE-312 EPSS 0.77% (53th pctl)

Overview

CVE-2015-1012 is a high-severity vulnerability affecting pfizer lifecare_pca_infusion_system_firmware. It was published on March 25, 2019 and has a CVSS 3.0 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access.

Remediation

Check the references section for vendor advisories and patches from pfizer. Update lifecare_pca_infusion_system_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
pfizer lifecare_pca_infusion_system_firmware 0 Affected

Frequently Asked Questions

What is CVE-2015-1012?

CVE-2015-1012 is a high-severity vulnerability affecting pfizer lifecare_pca_infusion_system_firmware. It was published on March 25, 2019 and has a CVSS 3.0 base score of 7.5 (HIGH).

How severe is CVE-2015-1012?

This vulnerability has a CVSS 3.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2015-1012?

Check the references section for vendor advisories and patches from pfizer. Update lifecare_pca_infusion_system_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2015-1012?

CyberStrike's AI-powered security agents can automatically detect CVE-2015-1012 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.