Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2017-11580

6.5 · MEDIUM
Published Jul 2, 2019 blipcare CWE-399 EPSS 1.43% (71th pctl)

Overview

CVE-2017-11580 is a medium-severity vulnerability affecting blipcare wi-fi_blood_pressure_monitor_firmware. It was published on July 2, 2019 and has a CVSS 3.0 base score of 6.5 (MEDIUM).

This vulnerability has a CVSS 3.0 base score of 6.5, rated MEDIUM. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

Technical Description

Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect "memcpy" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results

Remediation

Check the references section for vendor advisories and patches from blipcare. Update wi-fi_blood_pressure_monitor_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
blipcare wi-fi_blood_pressure_monitor_firmware 0 Affected

Frequently Asked Questions

What is CVE-2017-11580?

CVE-2017-11580 is a medium-severity vulnerability affecting blipcare wi-fi_blood_pressure_monitor_firmware. It was published on July 2, 2019 and has a CVSS 3.0 base score of 6.5 (MEDIUM).

How severe is CVE-2017-11580?

This vulnerability has a CVSS 3.0 base score of 6.5, rated MEDIUM. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2017-11580?

Check the references section for vendor advisories and patches from blipcare. Update wi-fi_blood_pressure_monitor_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2017-11580?

CyberStrike's AI-powered security agents can automatically detect CVE-2017-11580 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.