Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2017-12736

8.8 · HIGH
Published Dec 26, 2017 siemens CWE-1188 EPSS 1.00% (60th pctl)

Overview

CVE-2017-12736 is a high-severity vulnerability affecting siemens scalance_xb-200_firmware. It was published on December 26, 2017 and has a CVSS 3.1 base score of 8.8 (HIGH).

This vulnerability has a CVSS 3.1 base score of 8.8, rated HIGH. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

Technical Description

After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions.

This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.

Remediation

Check the references section for vendor advisories and patches from siemens. Update scalance_xb-200_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens scalance_xb-200_firmware 3.0 Affected
siemens scalance_xc-200_firmware 3.0 Affected
siemens scalance_xp-200_firmware 3.0 Affected
siemens scalance_xr300-wg_firmware 3.0 Affected
siemens scalance_xr-500_firmware 6.1 Affected
siemens scalance_xm-400_firmware 6.1 Affected
siemens ruggedcom_ros >= 0, < 5.0.1 Affected

Frequently Asked Questions

What is CVE-2017-12736?

CVE-2017-12736 is a high-severity vulnerability affecting siemens scalance_xb-200_firmware. It was published on December 26, 2017 and has a CVSS 3.1 base score of 8.8 (HIGH).

How severe is CVE-2017-12736?

This vulnerability has a CVSS 3.1 base score of 8.8, rated HIGH. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2017-12736?

Check the references section for vendor advisories and patches from siemens. Update scalance_xb-200_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2017-12736?

CyberStrike's AI-powered security agents can automatically detect CVE-2017-12736 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.