Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2017-14022

7.5 · HIGH
Published Dec 23, 2017 rockwellautomation CWE-20 EPSS 4.22% (90th pctl)

Overview

CVE-2017-14022 is a high-severity vulnerability affecting rockwellautomation factorytalk_alarms_and_events. It was published on December 23, 2017 and has a CVSS 3.0 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Remediation

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_alarms_and_events to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
rockwellautomation factorytalk_alarms_and_events 0 Affected

Frequently Asked Questions

What is CVE-2017-14022?

CVE-2017-14022 is a high-severity vulnerability affecting rockwellautomation factorytalk_alarms_and_events. It was published on December 23, 2017 and has a CVSS 3.0 base score of 7.5 (HIGH).

How severe is CVE-2017-14022?

This vulnerability has a CVSS 3.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2017-14022?

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_alarms_and_events to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2017-14022?

CyberStrike's AI-powered security agents can automatically detect CVE-2017-14022 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.