9.8 · CRITICALOverview
CVE-2017-2345 is a critical-severity vulnerability affecting juniper junos. It was published on July 17, 2017 and has a CVSS 3.0 base score of 9.8 (CRITICAL).
This vulnerability has a CVSS 3.0 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.
Technical Description
On Junos OS devices with SNMP enabled, a network based attacker with unfiltered access to the RE can cause the Junos OS snmpd daemon to crash and restart by sending a crafted SNMP packet. Repeated crashes of the snmpd daemon can result in a partial denial of service condition. Additionally, it may be possible to craft a malicious SNMP packet in a way that can result in remote code execution. SNMP is disabled in Junos OS by default. Junos OS devices with SNMP disabled are not affected by this issue. No other Juniper Networks products or platforms are affected by this issue. NOTE: This is a different issue than Cisco CVE-2017-6736, CVE-2017-6737, and CVE-2017-6738. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67; 12.3X48 prior to 12.3X48-D51, 12.3X48-D55; 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R2-S10, 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D122, 14.1X53-D44, 14.1X53-D50; 14.2 prior to 14.2R4-S9, 14.2R7-S7, 14.2R8; 15.
Remediation
Check the references section for vendor advisories and patches from juniper. Update junos to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
Affected Products
| Vendor | Product | Versions | Status |
|---|
Frequently Asked Questions
What is CVE-2017-2345?
CVE-2017-2345 is a critical-severity vulnerability affecting juniper junos. It was published on July 17, 2017 and has a CVSS 3.0 base score of 9.8 (CRITICAL).
How severe is CVE-2017-2345?
This vulnerability has a CVSS 3.0 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.
How do I fix or remediate CVE-2017-2345?
Check the references section for vendor advisories and patches from juniper. Update junos to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
How can CyberStrike help with CVE-2017-2345?
CyberStrike's AI-powered security agents can automatically detect CVE-2017-2345 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.
How CyberStrike Helps
AI agents map your attack surface to find vulnerabilities like this one.
Automated penetration testing that runs continuously, not just quarterly.
AI-driven PR review catches vulnerable dependencies before they ship.
Browser-based exploitation validates findings with real proof-of-concept.
Related CRITICAL CVEs from 2017
View all →Vulnerability in the Primavera P6 Enterprise Project Portfolio Management component of Oracle Primav
An issue was discovered in Radisys MRF Web Panel (SWMS) 9.0.1. The MSM_MACRO_NAME POST parameter in
SQL injection vulnerability in the Group Promotions module in the admin control panel in MyBB (aka M
A vulnerability in the web-based GUI of Cisco Prime Home could allow an unauthenticated, remote atta
IBM BigFix Platform could allow a remote attacker to execute arbitrary code on the system, caused by
IBM UrbanCode Deploy could allow a user to execute code using a specially crafted file upload that w
An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEF
An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Seri
An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.0
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV pr
An exploitable buffer overflow exists in the psnotifyd application of the Pharos PopUp printer clien
A buffer overflows exists in the psnotifyd application of the Pharos PopUp printer client version 9.