CVE-2017-6634

8.8 · HIGH
Published May 22, 2017 cisco CWE-352 EPSS 0.80% (54th pctl)

Overview

CVE-2017-6634 is a high-severity vulnerability affecting cisco industrial_ethernet_1000_series_firmware. It was published on May 22, 2017 and has a CVSS 3.0 base score of 8.8 (HIGH).

This vulnerability has a CVSS 3.0 base score of 8.8, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability in the Device Manager web interface of Cisco Industrial Ethernet 1000 Series Switches 1.3 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack against a user of an affected system. The vulnerability is due to insufficient CSRF protection by the Device Manager web interface. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link or visit an attacker-controlled website. A successful exploit could allow the attacker to submit arbitrary requests to an affected device via the Device Manager web interface and with the privileges of the user. Cisco Bug IDs: CSCvc88811.

Remediation

Check the references section for vendor advisories and patches from cisco. Update industrial_ethernet_1000_series_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2017-6634?

CVE-2017-6634 is a high-severity vulnerability affecting cisco industrial_ethernet_1000_series_firmware. It was published on May 22, 2017 and has a CVSS 3.0 base score of 8.8 (HIGH).

How severe is CVE-2017-6634?

This vulnerability has a CVSS 3.0 base score of 8.8, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2017-6634?

Check the references section for vendor advisories and patches from cisco. Update industrial_ethernet_1000_series_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2017-6634?

CyberStrike's AI-powered security agents can automatically detect CVE-2017-6634 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.