CVE-2017-7914

8.6 · HIGH
Published Jun 14, 2017 rockwellautomation CWE-882 EPSS 6.56% (93th pctl)

Overview

CVE-2017-7914 is a high-severity vulnerability affecting rockwellautomation panelview_plus_6_700-1500_firmware. It was published on June 14, 2017 and has a CVSS 3.0 base score of 8.6 (HIGH).

This vulnerability has a CVSS 3.0 base score of 8.6, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access.

Remediation

Check the references section for vendor advisories and patches from rockwellautomation. Update panelview_plus_6_700-1500_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2017-7914?

CVE-2017-7914 is a high-severity vulnerability affecting rockwellautomation panelview_plus_6_700-1500_firmware. It was published on June 14, 2017 and has a CVSS 3.0 base score of 8.6 (HIGH).

How severe is CVE-2017-7914?

This vulnerability has a CVSS 3.0 base score of 8.6, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2017-7914?

Check the references section for vendor advisories and patches from rockwellautomation. Update panelview_plus_6_700-1500_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2017-7914?

CyberStrike's AI-powered security agents can automatically detect CVE-2017-7914 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.