CVE-2017-9864 is a high-severity vulnerability affecting sma sunny_boy_3600_firmware. It was published on August 5, 2017 and has a CVSS 3.0 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Remediation

Check the references section for vendor advisories and patches from sma. Update sunny_boy_3600_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2017-9864?

CVE-2017-9864 is a high-severity vulnerability affecting sma sunny_boy_3600_firmware. It was published on August 5, 2017 and has a CVSS 3.0 base score of 7.5 (HIGH).

How severe is CVE-2017-9864?

This vulnerability has a CVSS 3.0 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2017-9864?

Check the references section for vendor advisories and patches from sma. Update sunny_boy_3600_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2017-9864?

CyberStrike's AI-powered security agents can automatically detect CVE-2017-9864 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.