CVE-2018-13800

7.3 · HIGH
Published Oct 10, 2018 siemens CWE-352 EPSS 0.63% (48th pctl)

Overview

CVE-2018-13800 is a high-severity vulnerability affecting siemens simatic_s7-1200_v4_firmware. It was published on October 10, 2018 and has a CVSS 3.0 base score of 7.3 (HIGH).

This vulnerability has a CVSS 3.0 base score of 7.3, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

Technical Description

A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 (All versions < V4.2.3). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify parts of the device configuration.

Remediation

Check the references section for vendor advisories and patches from siemens. Update simatic_s7-1200_v4_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens simatic_s7-1200_v4_firmware >= 0, < 4.2.3 Affected

Frequently Asked Questions

What is CVE-2018-13800?

CVE-2018-13800 is a high-severity vulnerability affecting siemens simatic_s7-1200_v4_firmware. It was published on October 10, 2018 and has a CVSS 3.0 base score of 7.3 (HIGH).

How severe is CVE-2018-13800?

This vulnerability has a CVSS 3.0 base score of 7.3, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2018-13800?

Check the references section for vendor advisories and patches from siemens. Update simatic_s7-1200_v4_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2018-13800?

CyberStrike's AI-powered security agents can automatically detect CVE-2018-13800 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.