Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2018-17924

8.6 · HIGH
Published Dec 7, 2018 rockwellautomation CWE-306 EPSS 4.33% (91th pctl)

Overview

CVE-2018-17924 is a high-severity vulnerability affecting rockwellautomation micrologix_1400_firmware. It was published on December 7, 2018 and has a CVSS 3.1 base score of 8.6 (HIGH).

This vulnerability has a CVSS 3.1 base score of 8.6, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.

Remediation

Check the references section for vendor advisories and patches from rockwellautomation. Update micrologix_1400_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
rockwellautomation 1756-en2f_series_c_firmware 0 Affected

Frequently Asked Questions

What is CVE-2018-17924?

CVE-2018-17924 is a high-severity vulnerability affecting rockwellautomation micrologix_1400_firmware. It was published on December 7, 2018 and has a CVSS 3.1 base score of 8.6 (HIGH).

How severe is CVE-2018-17924?

This vulnerability has a CVSS 3.1 base score of 8.6, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2018-17924?

Check the references section for vendor advisories and patches from rockwellautomation. Update micrologix_1400_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2018-17924?

CyberStrike's AI-powered security agents can automatically detect CVE-2018-17924 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.