CVE-2018-5438

6.3 · MEDIUM
Published Mar 20, 2018 philips CWE-613 EPSS 0.44% (37th pctl)

Overview

CVE-2018-5438 is a medium-severity vulnerability affecting philips intellispace_cardiovascular. It was published on March 20, 2018 and has a CVSS 3.0 base score of 6.3 (MEDIUM).

This vulnerability has a CVSS 3.0 base score of 6.3, rated MEDIUM. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.

Remediation

Check the references section for vendor advisories and patches from philips. Update intellispace_cardiovascular to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
philips intellispace_cardiovascular 0 Affected

Frequently Asked Questions

What is CVE-2018-5438?

CVE-2018-5438 is a medium-severity vulnerability affecting philips intellispace_cardiovascular. It was published on March 20, 2018 and has a CVSS 3.0 base score of 6.3 (MEDIUM).

How severe is CVE-2018-5438?

This vulnerability has a CVSS 3.0 base score of 6.3, rated MEDIUM. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2018-5438?

Check the references section for vendor advisories and patches from philips. Update intellispace_cardiovascular to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2018-5438?

CyberStrike's AI-powered security agents can automatically detect CVE-2018-5438 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.