Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2018-7112

5.5 · MEDIUM
Published Dec 3, 2018 hp EPSS 0.67% (49th pctl)

Overview

CVE-2018-7112 is a medium-severity vulnerability affecting hp integrated_lights-out_2_firmware. It was published on December 3, 2018 and has a CVSS 3.0 base score of 5.5 (MEDIUM).

This vulnerability has a CVSS 3.0 base score of 5.5, rated MEDIUM. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

The HPE-provided Windows firmware installer for certain Gen9, Gen8, G7,and G6 HPE servers allows local disclosure of privileged information. This issue was resolved in previously provided firmware updates as follows. The HPE Windows firmware installer was updated in the system ROM updates which also addressed the original Spectre/Meltdown set of vulnerabilities. At that time, the Windows firmware installer was also updated in the versions of HPE Integrated Lights-Out 2, 3, and 4 (iLO 2, 3, and 4) listed in the security bulletin. The updated HPE Windows firmware installer was released in the system ROM and HPE Integrated Lights-Out (iLO) releases documented in earlier HPE Security Bulletins: HPESBHF03805, HPESBHF03835, HPESBHF03831. Windows-based systems that have already been updated to the system ROM or iLO versions described in these security bulletins require no further action.

Remediation

Check the references section for vendor advisories and patches from hp. Update integrated_lights-out_2_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
hp integrated_lights-out_2_firmware >= 0, < 2.33 Affected
hp integrated_lights-out_3_firmware >= 0, < 1.90 Affected
hp integrated_lights-out_4_firmware >= 0, < 2.60 Affected
hp proliant_xl750f_gen9_server_firmware >= 0, < 2.56_01-22-2018 Affected
hp proliant_xl740f_gen9_server_firmware >= 0, < 2.56_01-22-2018 Affected
hp proliant_xl730f_gen9_server_firmware >= 0, < 2.56_01-22-2018 Affected
hp proliant_xl450_gen9_server_firmware >= 0, < 2.56_01-22-2018 Affected
hp proliant_xl270d_gen9_server_firmware >= 0, < 2.56_01-22-2018 Affected
hp proliant_xl270d_gen9_accelerator_tray_firmware >= 0, < 2.56_01-22-2018 Affected

Frequently Asked Questions

What is CVE-2018-7112?

CVE-2018-7112 is a medium-severity vulnerability affecting hp integrated_lights-out_2_firmware. It was published on December 3, 2018 and has a CVSS 3.0 base score of 5.5 (MEDIUM).

How severe is CVE-2018-7112?

This vulnerability has a CVSS 3.0 base score of 5.5, rated MEDIUM. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2018-7112?

Check the references section for vendor advisories and patches from hp. Update integrated_lights-out_2_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2018-7112?

CyberStrike's AI-powered security agents can automatically detect CVE-2018-7112 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.