Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2018-8868

6.2 · MEDIUM
Published Jul 3, 2018 medtronic CWE-749 EPSS 0.33% (26th pctl)

Overview

CVE-2018-8868 is a medium-severity vulnerability affecting medtronic 24950_mycarelink_monitor_firmware. It was published on July 3, 2018 and has a CVSS 3.1 base score of 6.2 (MEDIUM).

This vulnerability has a CVSS 3.1 base score of 6.2, rated MEDIUM. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.

Remediation

Check the references section for vendor advisories and patches from medtronic. Update 24950_mycarelink_monitor_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2018-8868?

CVE-2018-8868 is a medium-severity vulnerability affecting medtronic 24950_mycarelink_monitor_firmware. It was published on July 3, 2018 and has a CVSS 3.1 base score of 6.2 (MEDIUM).

How severe is CVE-2018-8868?

This vulnerability has a CVSS 3.1 base score of 6.2, rated MEDIUM. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2018-8868?

Check the references section for vendor advisories and patches from medtronic. Update 24950_mycarelink_monitor_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2018-8868?

CyberStrike's AI-powered security agents can automatically detect CVE-2018-8868 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.