CVE-2019-12777

7.8 · HIGH
Published Jun 7, 2019 enttec CWE-732 EPSS 0.41% (34th pctl)

Overview

CVE-2019-12777 is a high-severity vulnerability affecting enttec datagate_mk2_firmware. It was published on June 7, 2019 and has a CVSS 3.0 base score of 7.8 (HIGH).

This vulnerability has a CVSS 3.0 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

An issue was discovered on the ENTTEC Datagate MK2, Storm 24, Pixelator, and E-Streamer MK2 with firmware 70044_update_05032019-482. They replace secure and protected directory permissions (set as default by the underlying operating system) with highly insecure read, write, and execute directory permissions for all users. By default, /usr/local and all of its subdirectories should have permissions set to only allow non-privileged users to read and execute from the tree structure, and to deny users from creating or editing files in this location. The ENTTEC firmware startup script permits all users to read, write, and execute (rwxrwxrwx) from the /usr, /usr/local, /usr/local/dmxis, and /usr/local/bin/ directories.

Remediation

Check the references section for vendor advisories and patches from enttec. Update datagate_mk2_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2019-12777?

CVE-2019-12777 is a high-severity vulnerability affecting enttec datagate_mk2_firmware. It was published on June 7, 2019 and has a CVSS 3.0 base score of 7.8 (HIGH).

How severe is CVE-2019-12777?

This vulnerability has a CVSS 3.0 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2019-12777?

Check the references section for vendor advisories and patches from enttec. Update datagate_mk2_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2019-12777?

CyberStrike's AI-powered security agents can automatically detect CVE-2019-12777 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.