Menu

Star on GitHub · 3.2k

CVE-2019-6538

9.3 · CRITICAL

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CR…

Published Mar 25, 2019CWE-284EPSS 0.90%

Overview

CVE-2019-6538 is a critical-severity vulnerability. It was published on March 25, 2019 and has a CVSS 3.1 base score of 9.3 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.3, rated CRITICAL. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

Technical description

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

Remediation

Check the references section for vendor advisories, patches, and mitigation guidance. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Frequently asked questions

What is CVE-2019-6538?

CVE-2019-6538 is a critical-severity vulnerability. It was published on March 25, 2019 and has a CVSS 3.1 base score of 9.3 (CRITICAL).

How severe is CVE-2019-6538?

This vulnerability has a CVSS 3.1 base score of 9.3, rated CRITICAL. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2019-6538?

Check the references section for vendor advisories, patches, and mitigation guidance. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2019-6538?

CyberStrike is an open-source, AI-augmented pentesting engine. Rather than flag a version number, it tests whether an issue like CVE-2019-6538 is actually reachable in your own applications and APIs, then verifies each finding before reporting it. That tells you if the weakness is a real, exploitable risk in your environment or a false positive you can safely deprioritize.

Related CRITICAL CVEs from 2019

View all