Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2019-6576

6.5 · MEDIUM
Published May 14, 2019 siemens CWE-310 EPSS 1.75% (76th pctl)

Overview

CVE-2019-6576 is a medium-severity vulnerability affecting siemens simatic_hmi_comfort_panels_firmware. It was published on May 14, 2019 and has a CVSS 3.1 base score of 6.5 (MEDIUM).

This vulnerability has a CVSS 3.1 base score of 6.5, rated MEDIUM. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of th

Remediation

Check the references section for vendor advisories and patches from siemens. Update simatic_hmi_comfort_panels_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens simatic_hmi_comfort_panels_firmware >= 0, < 15.1 Affected
siemens simatic_hmi_comfort_outdoor_panels_firmware >= 0, < 15.1 Affected
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware >= 0, < 15.1 Affected
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware >= 0, < 15.1 Affected
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware >= 0, < 15.1 Affected
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware >= 0, < 15.1 Affected
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware >= 0, < 15.1 Affected
siemens simatic_wincc_\(tia_portal\) >= 0, < 15.1 Affected
siemens simatic_wincc_runtime >= 0, < 15.1 Affected

Frequently Asked Questions

What is CVE-2019-6576?

CVE-2019-6576 is a medium-severity vulnerability affecting siemens simatic_hmi_comfort_panels_firmware. It was published on May 14, 2019 and has a CVSS 3.1 base score of 6.5 (MEDIUM).

How severe is CVE-2019-6576?

This vulnerability has a CVSS 3.1 base score of 6.5, rated MEDIUM. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2019-6576?

Check the references section for vendor advisories and patches from siemens. Update simatic_hmi_comfort_panels_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2019-6576?

CyberStrike's AI-powered security agents can automatically detect CVE-2019-6576 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.