Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-11999

8.1 · HIGH
Published Jun 15, 2020 rockwellautomation CWE-20 EPSS 2.80% (85th pctl)

Overview

CVE-2020-11999 is a high-severity vulnerability affecting rockwellautomation factorytalk_linx. It was published on June 15, 2020 and has a CVSS 3.1 base score of 8.1 (HIGH).

This vulnerability has a CVSS 3.1 base score of 8.1, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

Technical Description

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.

Remediation

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_linx to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
rockwellautomation rslinx_classic 0 Affected

Frequently Asked Questions

What is CVE-2020-11999?

CVE-2020-11999 is a high-severity vulnerability affecting rockwellautomation factorytalk_linx. It was published on June 15, 2020 and has a CVSS 3.1 base score of 8.1 (HIGH).

How severe is CVE-2020-11999?

This vulnerability has a CVSS 3.1 base score of 8.1, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2020-11999?

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_linx to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-11999?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-11999 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.