CVE-2020-12005

7.5 · HIGH
Published Jun 15, 2020 rockwellautomation CWE-434 EPSS 1.84% (77th pctl)

Overview

CVE-2020-12005 is a high-severity vulnerability affecting rockwellautomation factorytalk_linx. It was published on June 15, 2020 and has a CVSS 3.1 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

Remediation

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_linx to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
rockwellautomation rslinx_classic 0 Affected

Frequently Asked Questions

What is CVE-2020-12005?

CVE-2020-12005 is a high-severity vulnerability affecting rockwellautomation factorytalk_linx. It was published on June 15, 2020 and has a CVSS 3.1 base score of 7.5 (HIGH).

How severe is CVE-2020-12005?

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2020-12005?

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_linx to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-12005?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-12005 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.