Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-12029

9.0 · CRITICAL
Published Jul 20, 2020 rockwellautomation CWE-20 EPSS 46.97% (99th pctl)

Overview

CVE-2020-12029 is a critical-severity vulnerability affecting rockwellautomation factorytalk_view. It was published on July 20, 2020 and has a CVSS 3.1 base score of 9.0 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.0, rated CRITICAL. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

Technical Description

All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.

Remediation

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_view to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2020-12029?

CVE-2020-12029 is a critical-severity vulnerability affecting rockwellautomation factorytalk_view. It was published on July 20, 2020 and has a CVSS 3.1 base score of 9.0 (CRITICAL).

How severe is CVE-2020-12029?

This vulnerability has a CVSS 3.1 base score of 9.0, rated CRITICAL. It requires local or adjacent network access to exploit. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2020-12029?

Check the references section for vendor advisories and patches from rockwellautomation. Update factorytalk_view to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-12029?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-12029 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.