Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-15787

9.8 · CRITICAL
Published Sep 9, 2020 siemens CWE-305 EPSS 1.48% (72th pctl)

Overview

CVE-2020-15787 is a critical-severity vulnerability affecting siemens simatic_hmi_united_comfort_panels_firmware. It was published on September 9, 2020 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Remediation

Check the references section for vendor advisories and patches from siemens. Update simatic_hmi_united_comfort_panels_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2020-15787?

CVE-2020-15787 is a critical-severity vulnerability affecting siemens simatic_hmi_united_comfort_panels_firmware. It was published on September 9, 2020 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

How severe is CVE-2020-15787?

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2020-15787?

Check the references section for vendor advisories and patches from siemens. Update simatic_hmi_united_comfort_panels_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-15787?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-15787 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.