CVE-2020-25176

9.1 · CRITICAL
Published Mar 18, 2022 schneider-electric CWE-23 EPSS 6.42% (93th pctl)

Overview

CVE-2020-25176 is a critical-severity vulnerability affecting schneider-electric easergy_t300_firmware. It was published on March 18, 2022 and has a CVSS 3.1 base score of 9.1 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.1, rated CRITICAL. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

Technical Description

Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.

Remediation

Check the references section for vendor advisories and patches from schneider-electric. Update easergy_t300_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
schneider-electric easergy_t300_firmware 0 Affected
schneider-electric easergy_c5_firmware >= 0, < 1.1.0 Affected
schneider-electric micom_c264_firmware >= 0, < d6.1 Affected
schneider-electric saitel_dp_firmware 0 Affected
schneider-electric saitel_dr_firmware 0 Affected
schneider-electric scd2200_firmware 0 Affected
rockwellautomation aadvance_controller 0 Affected
rockwellautomation isagraf_free_runtime 0 Affected
rockwellautomation isagraf_runtime >= 5.0, < 6.0 Affected

Frequently Asked Questions

What is CVE-2020-25176?

CVE-2020-25176 is a critical-severity vulnerability affecting schneider-electric easergy_t300_firmware. It was published on March 18, 2022 and has a CVSS 3.1 base score of 9.1 (CRITICAL).

How severe is CVE-2020-25176?

This vulnerability has a CVSS 3.1 base score of 9.1, rated CRITICAL. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2020-25176?

Check the references section for vendor advisories and patches from schneider-electric. Update easergy_t300_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-25176?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-25176 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.