Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-28209

7.0 · HIGH
Published Nov 19, 2020 schneider-electric CWE-428 EPSS 0.28% (20th pctl)

Overview

CVE-2020-28209 is a high-severity vulnerability affecting schneider-electric enterprise_server_installer. It was published on November 19, 2020 and has a CVSS 3.1 base score of 7.0 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.0, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administrator privileges so the vulnerability is only valid if the application has been installed on a non-secure location.

Remediation

Check the references section for vendor advisories and patches from schneider-electric. Update enterprise_server_installer to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
schneider-electric enterprise_server_installer 1.9 Affected

Frequently Asked Questions

What is CVE-2020-28209?

CVE-2020-28209 is a high-severity vulnerability affecting schneider-electric enterprise_server_installer. It was published on November 19, 2020 and has a CVSS 3.1 base score of 7.0 (HIGH).

How severe is CVE-2020-28209?

This vulnerability has a CVSS 3.1 base score of 7.0, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2020-28209?

Check the references section for vendor advisories and patches from schneider-electric. Update enterprise_server_installer to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-28209?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-28209 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.