Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-28219

7.8 · HIGH
Published Dec 11, 2020 schneider-electric CWE-522 EPSS 0.31% (23th pctl)

Overview

CVE-2020-28219 is a high-severity vulnerability affecting schneider-electric ecostruxure_geo_scada_expert_2019. It was published on December 11, 2020 and has a CVSS 3.1 base score of 7.8 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.

Remediation

Check the references section for vendor advisories and patches from schneider-electric. Update ecostruxure_geo_scada_expert_2019 to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
schneider-electric ecostruxure_geo_scada_expert_2019 81.7268.1 Affected
schneider-electric ecostruxure_geo_scada_expert_2020 83.7551.1 Affected

Frequently Asked Questions

What is CVE-2020-28219?

CVE-2020-28219 is a high-severity vulnerability affecting schneider-electric ecostruxure_geo_scada_expert_2019. It was published on December 11, 2020 and has a CVSS 3.1 base score of 7.8 (HIGH).

How severe is CVE-2020-28219?

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2020-28219?

Check the references section for vendor advisories and patches from schneider-electric. Update ecostruxure_geo_scada_expert_2019 to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-28219?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-28219 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.