Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-6998

5.8 · MEDIUM
Published Jul 27, 2022 rockwellautomation CWE-20 EPSS 2.16% (81th pctl)

Overview

CVE-2020-6998 is a medium-severity vulnerability affecting rockwellautomation armor_compact_guardlogix_5370_firmware. It was published on July 27, 2022 and has a CVSS 3.1 base score of 5.8 (MEDIUM).

This vulnerability has a CVSS 3.1 base score of 5.8, rated MEDIUM. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.

Remediation

Check the references section for vendor advisories and patches from rockwellautomation. Update armor_compact_guardlogix_5370_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
rockwellautomation armor_compact_guardlogix_5370_firmware 0 Affected
rockwellautomation compact_guardlogix_5370_firmware 0 Affected
rockwellautomation compactlogix_5370_l1_firmware 0 Affected
rockwellautomation compactlogix_5370_l2_firmware 0 Affected
rockwellautomation compactlogix_5370_l3_firmware 0 Affected
rockwellautomation controllogix_5570_firmware 0 Affected
rockwellautomation guardlogix_5560_firmware 0 Affected
rockwellautomation guardlogix_5570_firmware 0 Affected
rockwellautomation guardlogix_5580_firmware 0 Affected

Frequently Asked Questions

What is CVE-2020-6998?

CVE-2020-6998 is a medium-severity vulnerability affecting rockwellautomation armor_compact_guardlogix_5370_firmware. It was published on July 27, 2022 and has a CVSS 3.1 base score of 5.8 (MEDIUM).

How severe is CVE-2020-6998?

This vulnerability has a CVSS 3.1 base score of 5.8, rated MEDIUM. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2020-6998?

Check the references section for vendor advisories and patches from rockwellautomation. Update armor_compact_guardlogix_5370_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-6998?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-6998 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.