Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-7575

6.1 · MEDIUM
Published Apr 14, 2020 siemens CWE-80 EPSS 0.66% (49th pctl)

Overview

CVE-2020-7575 is a medium-severity vulnerability affecting siemens climatix_pol908_firmware. It was published on April 14, 2020 and has a CVSS 3.1 base score of 6.1 (MEDIUM).

This vulnerability has a CVSS 3.1 base score of 6.1, rated MEDIUM. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions.

Remediation

Check the references section for vendor advisories and patches from siemens. Update climatix_pol908_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens climatix_pol909_firmware >= 0, < 11.32 Affected

Frequently Asked Questions

What is CVE-2020-7575?

CVE-2020-7575 is a medium-severity vulnerability affecting siemens climatix_pol908_firmware. It was published on April 14, 2020 and has a CVSS 3.1 base score of 6.1 (MEDIUM).

How severe is CVE-2020-7575?

This vulnerability has a CVSS 3.1 base score of 6.1, rated MEDIUM. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2020-7575?

Check the references section for vendor advisories and patches from siemens. Update climatix_pol908_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-7575?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-7575 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.