Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2020-7585

7.8 · HIGH
Published Jun 10, 2020 siemens CWE-427 EPSS 0.43% (36th pctl)

Overview

CVE-2020-7585 is a high-severity vulnerability affecting siemens simatic_pcs_7. It was published on June 10, 2020 and has a CVSS 3.1 base score of 7.8 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.

Remediation

Check the references section for vendor advisories and patches from siemens. Update simatic_pcs_7 to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens simatic_step_7 >= 0, < 5.6 Affected
siemens sinamics_starter >= 0, < 5.4 Affected

Frequently Asked Questions

What is CVE-2020-7585?

CVE-2020-7585 is a high-severity vulnerability affecting siemens simatic_pcs_7. It was published on June 10, 2020 and has a CVSS 3.1 base score of 7.8 (HIGH).

How severe is CVE-2020-7585?

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2020-7585?

Check the references section for vendor advisories and patches from siemens. Update simatic_pcs_7 to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-7585?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-7585 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.