Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2021-35533

7.5 · HIGH
Published Nov 26, 2021 hitachienergy CWE-20 EPSS 0.92% (57th pctl)

Overview

CVE-2021-35533 is a high-severity vulnerability affecting hitachienergy rtu500_firmware. It was published on November 26, 2021 and has a CVSS 3.1 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).

Remediation

Check the references section for vendor advisories and patches from hitachienergy. Update rtu500_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2021-35533?

CVE-2021-35533 is a high-severity vulnerability affecting hitachienergy rtu500_firmware. It was published on November 26, 2021 and has a CVSS 3.1 base score of 7.5 (HIGH).

How severe is CVE-2021-35533?

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2021-35533?

Check the references section for vendor advisories and patches from hitachienergy. Update rtu500_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2021-35533?

CyberStrike's AI-powered security agents can automatically detect CVE-2021-35533 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.