CVE-2022-39290

8.0 · HIGH
Published Oct 7, 2022 zoneminder CWE-287 EPSS 5.85% (93th pctl)

Overview

CVE-2022-39290 is a high-severity vulnerability affecting zoneminder zoneminder. It was published on October 7, 2022 and has a CVSS 3.1 base score of 8.0 (HIGH).

This vulnerability has a CVSS 3.1 base score of 8.0, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

Technical Description

ZoneMinder is a free, open source Closed-circuit television software application. In affected versions authenticated users can bypass CSRF keys by modifying the request supplied to the Zoneminder web application. These modifications include replacing HTTP POST with an HTTP GET and removing the CSRF key from the request. An attacker can take advantage of this by using an HTTP GET request to perform actions with no CSRF protection. This could allow an attacker to cause an authenticated user to perform unexpected actions on the web application. Users are advised to upgrade as soon as possible. There are no known workarounds for this issue.

Remediation

Check the references section for vendor advisories and patches from zoneminder. Update zoneminder to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
zoneminder zoneminder >= 0, < 1.36.27 Affected

Frequently Asked Questions

What is CVE-2022-39290?

CVE-2022-39290 is a high-severity vulnerability affecting zoneminder zoneminder. It was published on October 7, 2022 and has a CVSS 3.1 base score of 8.0 (HIGH).

How severe is CVE-2022-39290?

This vulnerability has a CVSS 3.1 base score of 8.0, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2022-39290?

Check the references section for vendor advisories and patches from zoneminder. Update zoneminder to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2022-39290?

CyberStrike's AI-powered security agents can automatically detect CVE-2022-39290 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.