CVE-2024-39563

7.3 · HIGH
Published Oct 11, 2024 juniper CWE-77 EPSS 1.34% (69th pctl)

Overview

CVE-2024-39563 is a high-severity vulnerability affecting juniper junos_space. It was published on October 11, 2024 and has a CVSS 3.1 base score of 7.3 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.3, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A Command Injection vulnerability in Juniper Networks Junos Space allows an unauthenticated, network-based attacker sending a specially crafted request to execute arbitrary shell commands on the Junos Space Appliance, leading to remote command execution by the web application, gaining complete control of the device.

A specific script in the Junos Space web application allows attacker-controlled input from a GET request without sufficient input sanitization. A specially crafted request can exploit this vulnerability to execute arbitrary shell commands on the Junos Space Appliance.

This issue affects Junos Space 24.1R1. Previous versions of Junos Space are unaffected by this vulnerability.

Remediation

Check the references section for vendor advisories and patches from juniper. Update junos_space to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2024-39563?

CVE-2024-39563 is a high-severity vulnerability affecting juniper junos_space. It was published on October 11, 2024 and has a CVSS 3.1 base score of 7.3 (HIGH).

How severe is CVE-2024-39563?

This vulnerability has a CVSS 3.1 base score of 7.3, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2024-39563?

Check the references section for vendor advisories and patches from juniper. Update junos_space to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2024-39563?

CyberStrike's AI-powered security agents can automatically detect CVE-2024-39563 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.