CVE-2024-7441

8.8 · HIGH
Published Aug 3, 2024 vivotek CWE-121 EPSS 8.13% (95th pctl)

Overview

CVE-2024-7441 is a high-severity vulnerability affecting vivotek sd9364_firmware. It was published on August 3, 2024 and has a CVSS 3.1 base score of 8.8 (HIGH).

This vulnerability has a CVSS 3.1 base score of 8.8, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

Technical Description

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

Remediation

Check the references section for vendor advisories and patches from vivotek. Update sd9364_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2024-7441?

CVE-2024-7441 is a high-severity vulnerability affecting vivotek sd9364_firmware. It was published on August 3, 2024 and has a CVSS 3.1 base score of 8.8 (HIGH).

How severe is CVE-2024-7441?

This vulnerability has a CVSS 3.1 base score of 8.8, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2024-7441?

Check the references section for vendor advisories and patches from vivotek. Update sd9364_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2024-7441?

CyberStrike's AI-powered security agents can automatically detect CVE-2024-7441 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.