Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2025-20165

7.5 · HIGH
Published Jan 22, 2025 cisco CWE-789 EPSS 0.86% (56th pctl)

Overview

CVE-2025-20165 is a high-severity vulnerability affecting cisco broadworks_network_server. It was published on January 22, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability in the SIP processing subsystem of Cisco BroadWorks could allow an unauthenticated, remote attacker to halt the processing of incoming SIP requests, resulting in a denial of service (DoS) condition.

This vulnerability is due to improper memory handling for certain SIP requests. An attacker could exploit this vulnerability by sending a high number of SIP requests to an affected system. A successful exploit could allow the attacker to exhaust the memory that was allocated to the Cisco BroadWorks Network Servers that handle SIP traffic. If no memory is available, the Network Servers can no longer process incoming requests, resulting in a DoS condition that requires manual intervention to recover.

Remediation

Check the references section for vendor advisories and patches from cisco. Update broadworks_network_server to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
cisco broadworks_network_server >= 0, < 2024.11 Affected

Frequently Asked Questions

What is CVE-2025-20165?

CVE-2025-20165 is a high-severity vulnerability affecting cisco broadworks_network_server. It was published on January 22, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).

How severe is CVE-2025-20165?

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2025-20165?

Check the references section for vendor advisories and patches from cisco. Update broadworks_network_server to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2025-20165?

CyberStrike's AI-powered security agents can automatically detect CVE-2025-20165 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.