CVE-2025-21605
7.5 · HIGHOverview
CVE-2025-21605 is a high-severity vulnerability affecting redis redis. It was published on April 23, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).
This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.
Technical Description
Redis is an open source, in-memory database that persists on disk. In versions starting at 2.6 and prior to 7.4.3, An unauthenticated client can cause unlimited growth of output buffers, until the server runs out of memory or is killed. By default, the Redis configuration does not limit the output buffer of normal clients (see client-output-buffer-limit). Therefore, the output buffer can grow unlimitedly over time. As a result, the service is exhausted and the memory is unavailable. When password authentication is enabled on the Redis server, but no password is provided, the client can still cause the output buffer to grow from "NOAUTH" responses until the system will run out of memory. This issue has been patched in version 7.4.3. An additional workaround to mitigate this problem without patching the redis-server executable is to block access to prevent unauthenticated users from connecting to Redis. This can be done in different ways. Either using network access control tools like fi
Remediation
Check the references section for vendor advisories and patches from redis. Update redis to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
Affected Products
| Vendor | Product | Versions | Status |
|---|---|---|---|
| redis | redis | >= 2.6.0, < 6.2.18 | Affected |
| lfprojects | valkey | >= 7.2.4, < 7.2.9 | Affected |
References
Frequently Asked Questions
What is CVE-2025-21605?
CVE-2025-21605 is a high-severity vulnerability affecting redis redis. It was published on April 23, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).
How severe is CVE-2025-21605?
This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.
How do I fix or remediate CVE-2025-21605?
Check the references section for vendor advisories and patches from redis. Update redis to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
How can CyberStrike help with CVE-2025-21605?
CyberStrike's AI-powered security agents can automatically detect CVE-2025-21605 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.
How CyberStrike Helps
AI agents map your attack surface to find vulnerabilities like this one.
Automated penetration testing that runs continuously, not just quarterly.
AI-driven PR review catches vulnerable dependencies before they ship.
Browser-based exploitation validates findings with real proof-of-concept.
Related HIGH CVEs from 2025
View all →HCL MyXalytics is affected by out-of-band resource load (HTTP) vulnerability. An attacker can deplo
The NextEPC MME <= 1.0.1 (fixed in commit a8492c9c5bc0a66c6999cb5a263545b32a4109df) contains a stack
A flaw was found in the Red Hat Advanced Cluster Security (RHACS) portal. When rendering a table vie
A Stored Cross-Site Scripting (XSS) vulnerability exists in the chat file upload functionality of op
A: Improper Neutralization of Input During Web Page Generation vulnerability in SUSE rancher allows
Mbed TLS before 3.6.4 allows a use-after-free in certain situations of applications that are develop
In iperf before 3.19.1, net.c has a buffer overflow when --skip-rx-copy is used (for MSG_TRUNC in re
Missing authorization in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure befor
Memory corruptions can be remotely triggered in the Control-M/Agent when SSL/TLS communication is co
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerab
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerab
An issue in Orban Optimod 5950, Optimod 5950HD, Optimod 5750, Optimod 5750HD, Optimod Trio Optimod v